LSKG - Ⅰ two-stage deviation switch, bidirectional manual, bidirectional automatic, LSKG - Ⅰ
LSKG - Ⅰ two-stage deviation switch, bidirectional manual rope pulling switch, bidirectional automatic rope pulling switch,two-stage deviation switch, bidirectional manual rope pulling switch, bidirectional automatic rope pulling switch, LSKG - Ⅰ bidirectional rope pulling switch is a protective device used for emergency shutdown of tape transportation airports. When an emergency occurs, activating the rope switch anywhere on site can trigger a shutdown signal.
- LSKG-I two-stage deviation switch, bi-directional manual, bi-directional automatic,
- ZHUOXIN
- 24-380v
- IP65
- TT, Paypal, Credit card, Western union
- +86-15163766288
- LSKG - Ⅰ two-stage deviation switch, bidirectional manual rope pulling switch, bidirectional automatic rope pulling switch,two-stage deviation switch, bidirectional manual rope pulling switch, bidirectional automatic rope pulling switch, LSKG - Ⅰ bidirectional rope pulling switch is a protective device used for emergency shutdown of tape transportation airports. When an emergency occurs, activating the rope switch anywhere on site can trigger a shutdown signal.
Description
LSKG - Ⅰ two-stage deviation switch, bidirectional manual rope pulling switch, bidirectional automatic rope pulling switch. Briefly introduce the two-stage deviation switch, bidirectional manual rope pulling switch, bidirectional automatic rope pulling switch. LSKG - Ⅰ bidirectional rope pulling switch is a protective device used for emergency shutdown of tape transportation airports. When an emergency occurs, activating the rope switch anywhere on site can trigger a shutdown signal< br /> Two level deviation switch, bidirectional manual rope pulling switch, bidirectional automatic rope pulling switch, detailed introduction of LSKG - Ⅰ Two level deviation switch, bidirectional manual rope pulling switch, bidirectional automatic rope pulling switch, LSKG - Ⅰ Purpose:
The bidirectional rope pulling switch is a protective device used for emergency shutdown of tape transportation airports. When an emergency occurs, activating the rope switch anywhere on site can trigger a shutdown signal. Model meaning:
Usage conditions: (working environment)
Environmental temperature: -40 ℃~+60 ℃& nbsp; Relative humidity: not more than 90%< Atmospheric pressure: 80-110kpa& nbsp; Altitude: not exceeding 2000M< Service life: 10000 switch actions& nbsp; Insulation voltage: The AC1000V test lasts for 1 minute< Main technical indicators:; Model contact
Capacity contact quantity Action force
(kg) Reset
Form of operation
Travel limit
Travel protection
Grade weight
(kg) Normally open and normally closed LSKG - I≤ 380V
≤ 3A 1112± 2 automatic reset 15± 2mm20± 2mmIP551.8LSKG-Ⅱ≤ 380V
≤ 3A 1112± 2 manual reset 15± 2mm20± 2mmIP552.0 Working principle and structural features: This machine adopts a rotating cam structure. When either side of the rope switch is pulled or both sides of the rope are pulled simultaneously, the cam can be driven to switch the switch action and send a stop signal< The LSKG-I bidirectional rope switch adopts an automatic reset method< The LSKG-II bidirectional rope switch adopts a manual reset method. After troubleshooting, the operator must pull out the reset lever in order to restore the machine to normal operation. CJZQ-H15L CJZQ-H10L JZFS-B32 JZFS-B25 JZFS-B20 JZFS-B10 JZFS-B8 JZF-F50H JZF-F40H JZF-F32H JZF-F25H JZF-F20H JZF-F15H JZF-F10H JZF-L32H JZF-L25H JZF-L20H JZF-L15H JZF-L10H 34E2-B4B 24E2-B4B 23E2-B4B 22E2-B4B 34E-B4B 24E-B4B 23E-B4B 22E-B4B 35D2-63(B)
The bidirectional rope pulling switch is a protective device used for emergency shutdown of tape transportation airports. When an emergency occurs, activating the rope switch anywhere on site can trigger a shutdown signal. Model meaning:
Usage conditions: (working environment)
Environmental temperature: -40 ℃~+60 ℃& nbsp; Relative humidity: not more than 90%< Atmospheric pressure: 80-110kpa& nbsp; Altitude: not exceeding 2000M< Service life: 10000 switch actions& nbsp; Insulation voltage: The AC1000V test lasts for 1 minute< Main technical indicators:; Model contact
Capacity contact quantity Action force
(kg) Reset
Form of operation
Travel limit
Travel protection
Grade weight
(kg) Normally open and normally closed LSKG - I≤ 380V
≤ 3A 1112± 2 automatic reset 15± 2mm20± 2mmIP551.8LSKG-Ⅱ≤ 380V
≤ 3A 1112± 2 manual reset 15± 2mm20± 2mmIP552.0 Working principle and structural features: This machine adopts a rotating cam structure. When either side of the rope switch is pulled or both sides of the rope are pulled simultaneously, the cam can be driven to switch the switch action and send a stop signal< The LSKG-I bidirectional rope switch adopts an automatic reset method< The LSKG-II bidirectional rope switch adopts a manual reset method. After troubleshooting, the operator must pull out the reset lever in order to restore the machine to normal operation. CJZQ-H15L CJZQ-H10L JZFS-B32 JZFS-B25 JZFS-B20 JZFS-B10 JZFS-B8 JZF-F50H JZF-F40H JZF-F32H JZF-F25H JZF-F20H JZF-F15H JZF-F10H JZF-L32H JZF-L25H JZF-L20H JZF-L15H JZF-L10H 34E2-B4B 24E2-B4B 23E2-B4B 22E2-B4B 34E-B4B 24E-B4B 23E-B4B 22E-B4B 35D2-63(B)