Conveyor switch

Two stage deviation switch HFKPT1-10-45sx HFKPT1-10-45

Two level deviation switch HFKPT1-10-45 is used for conventional belt conveyors: underground, cable support belt conveyors: ship loading and unloading systems; Stacking/reclaiming conveyor; Tilt and shuttle conveyors; Crane, excavator, boom limit: skirt feeder/conveyor: heavy-duty limit switch detects the deviation of the tape, which is a protective device for automatic alarm and shutdown of the tape machine control. Widely used in various belt conveyor equipment in fields such as metallurgy, coal, cement and building materials, mining, power, ports, metallurgy, chemical industry, etc

  • Two stage deviation switch HFKPT1-10-45
  • ZHUOXIN
  • 24-380v
  • IP65
  • TT, Paypal, Credit card, Western union
  • +86-15163766288
  • Two level deviation switch HFKPT1-10-45 is used for conventional belt conveyors: underground, cable support belt conveyors: ship loading and unloading systems; Stacking/reclaiming conveyor; Tilt and shuttle conveyors; Crane, excavator, boom limit: skirt feeder/conveyor: heavy-duty limit switch detects the deviation of the tape, which is a protective device for automatic alarm and shutdown of the tape machine control. Widely used in various belt conveyor equipment in fields such as metallurgy, coal, cement and building materials, mining, power, ports, metallurgy, chemical industry, etc

Description

Conveyor switch

Two level deviation switch HFKPT1-10-45 Two level deviation switch HFKPT1-10-45 Working principle Two level deviation switch HFKPT1-10-45 is installed on both sides of the belt conveyor, 1-3 meters away from the front and rear ends of the belt conveyor. When the belt deviates, the edge of the belt presses against the gear wheel, forcing it to deflect and causing the limit switch to operate. To reduce friction between the gear wheel and the belt, the main body of the gear wheel is made of bearings. When a minor deviation accident occurs (10 °), the * group contacts of the two-stage deviation switch act and issue an accident warning signal. When a serious deviation accident occurs (45 °), the second set of contacts of the two-stage deviation switch will act, which can automatically stop the conveyor. Two stage deviation switch HFKPT1-10-45. Operating environment conditions: a. Environmental temperature: -40 ℃~60 ℃ b. Relative humidity not exceeding 85% c. Sea level height not exceeding 2000md. Service life: 100000 switch actions e. Insulation voltage: AC1000 test for 1 minute f. Contact capacity: ≤ AC380 ≤ 3Ag. Protection level: IP67 Two stage deviation switch HFKPT1-10-45. Precautions: 1. The gear wheel of the deviation switch should be kept perpendicular to the belt. 2. It is recommended to maintain a distance of 120-160mm between the gear wheel of the deviation switch and the edge of the belt. 3. The base of the deviation switch is firmly fixed. Technical indicators 1. Rated voltage: AC380V2. Rated current: 5A3 Number of contacts: Two independent normally open and normally closed contacts. 4. Housing protection level: DT type dustproof housing, protection level IP67. 5. Surrounding environment temperature: -25~80 ℃. 6. The switch can operate under vibration conditions with a frequency of 10-60Hz and an amplitude of 0.75mm (10g). 7. External dimensions: Housing L x W x H (mm) 190 x 135 x 100. 8. Operating power: 5-7 kg 9. Communication interface: RS485 address coding network communication (effective for models with suffix BM) waterproof junction box, WZP-270S, WRE-625, WZP-012S, K-250CD, WRP-100, WRE-010, WRE-220A, WRN-010, WRR2-010, WRN2-631, WZP2-010, WZP2-221, WZP2-220, WZP-231, WZP-230, WZP2-1312A, WZP2-106S, WRET2-31, WRN-235T, WRE-235T movable thermocouple thermal Resistance, WRNR2-01, WERE2-15A, WRER2-13, WRNR2-13, WERE-13, WRNR-13, WRER2-12, WRER-01, WRNR-01, WERE2-01, WRER-12, WRET-001, WRE-625, WZPK2-535SA, WRN-15B, WRE2-14B, WRNR2-15, WRER-15, WZP-011, WZC-010A, WZP-035S, WRN-002, WRP-010, WRE-520 right angle elbow thermocouple, WZPM-2012, WZP-203S, WSSX electrical Contact bimetallic thermometer, WZPK-426U,WZPK-166U,WZPK-525U,WZPK-165U,WZPK-425U,.WZPK-424U,WZPK-326U,WZPK-323U,WZPK-226U,WZPK-224U,WZPK-223U,WZPK-233U,WZPK-405U,WZPK-135U,WZPK-136U,WZP-104U,WZPK-333U,WZPK-103U,WZPK-336U,WZPK-263U,WZPK-335U,WZPK-363U,WZPK-465U,WZPK-464U,WZPK-266U,WZPK-565U,WZPK-276U,WZPK-375U,WZPK-476U,WZPK2-475SA,WZPK-474S,WZPK-133U,WZPK-473S,WZPK2-376SA,WZPK-506U,WZPK-504U,WZPK-505U,WZPK-374S,WZPK-375S,WZPK2-375SA,WZPK-376S,WZPK2-276SA,WZPK-276S,WZPK2-275SA,WZPK-503S,WZPK2-406SA,WZPK2-405SA,WZPK-406S,WZPK-4055,WZPK-404S,WZPK-304U,WZPK-206U,WZPK-205U,WZPK-203U,WZPK2-305SA,WZPK-306S,WZPK-305S,WZPK-303S,WZPK2-205SA,WZPK-26S,WZPK-205S, WZPK-204S, WZPK-203S, WZPK-106SA, WZP-430B,. WZPK-2312U, WZPK-176SA, WZPK-175SA, WZPK-176S, WZPK-163S, WZPK2-466SA, WZPK2-366SA, WZPK2-365SA, WZPK-366S, WZPK-364S, WZPK-364S, WZPK-363S, WZPK-266SA, WZPK-266S, WZPK-265S, WZPK-264S WZP-166S, WZPK-263S, WZPK-165S Armored Platinum Resistors, WZPK-535S,WZPK-533S,WZPK-534S,WZPK2-436SA,WZPK2-435SA,WZPK-435S,WZPK-434S,WZPK-433S,WZPK2-336SA,WZPK-235U,WZPK-134U,WZPK-236S,WZPK2-335SA,WZPK-336S,WZPK-235S,WZPK-325U,WZPK-234S,WZPK-335S,WZPK-404U,WZPK-126U,WZPK-334S,WZPK-233S,WZPK-365U,WZPK2-136SA,WZPK-333S,WZPK2-236SA,WZPK2-135SA,WZPK-136S,WZPK2-235SA,WZPK-135S,WZPK-134S,WZPK-524U,WZPK-123U,.WZPK2-525SA,WZPK-525S,WZPK-524S,WZPK-523S,WZPK2-425SA,WZPK-425S,WZPK-424S,WZP2-44SAB,WZPK-423S,WZPK-326S,WZPK2-325SA,WZPK-325S,WZPK-323S,WZPK-324S,WZPK2-226SA,WZPK2-225SA,WZPK-226S,WZPK-225S,WZPK-223S,WZPK2-126SA,WZPK2-125SA,WZPK-125S,.WZPK-126S,WZPK-124S,WZPK-123S,WZPK2-506SA, WZPK2-505SA, WZP2-420D, WZC-430B, WZPK-164S, WZPK-575S, WZPK-505S, WZPK-565S, WZPK-566S, WZP-431C, WZPK-466U Armored Platinum Thermal Wave Film Resistor, WZPK-105U, WZPK-324U, WZPK-364U, WZPK-264U, WZPK-163U, WZPK-523U, WZP-421D, WZPK-103U, WRP2-121B, WZP2-74S Chemical Explosion proof Heat Resistance, WRR-131, WRR2-131, WRN-230D, WRE-210D, WRN-430D, WRNK-431, WRK-240, WRK-520, WRS-132, WRT-620, WRN-130, WRN-130, WRNK-231, WREK-232, WRE-621A, WZPK-133S, WRN-631, WRE2-235T, WRER2-13, WRPB-230, WRE-621, WRN2-621,. WZPM-201S, WZPK2-306SA, WZP-205S, WREK-1315, WRET-01, WZPK2-306SA PF-130 WZPF-130 WZPF-430, WRNT-11, WZCM, WZPM, SBW series, WRR-120,WRR-121,WRP-120,WRP-121,WRN-122,WRN-123, Platinum rhodium thermocouple, armored platinum rhodium thermocouple, cement factory thermocouple, glass furnace thermocouple, armored thermocouple, WRN-130F, WRN-230F, WRN-330F, WRN-430F, WZP-002, WZP2-631, WZP2-621A, WZP2-621, WZP-430, WZP2-421, WZP2-420, WZP-420, WZC-320, WZP2-331, WZP2-321, WZP2-320, WZP-631 331, WZP-330, WZP-321, WZP-320, WZC-220A, WZC-230, WZC-220, WZP-221A, WZP2-231, WZP2-230 dual platinum thermistors, WZP-3212A,WRE2-235T,WRNT-001,WZP-221,WZP-220,WREK、WRNK、WRCK,WREK-1314,WREK-440,WRNK-440,WZC-200,WRN-621A,WZP-24SA,WRE2-631,WRE-220,WZP-003,WZPM-101U, Electric contact pressure thermometer WTZ-288 WTQ-288,WTZ-280B-F,WTZ280、WTQ280,WTZ-280,WZPN-431,WZPN2-131,WZPN2-331,WZPN-130,WRN2-230-F,WZPK-526U,WZCN-430,WZCN-330,WZCN-130,WZCN-230,WZPN-131,WZP-431D,WZPN-430,WZPN2-130,WZPN-330,WZPN-331,

Tags

Get the latest price? We'll respond as soon as possible(within 12 hours)