CJZCP-2 waterproof two-stage deviation switch
CJZCP-2 waterproof two-level deviation switch There are ordinary type, wiring chamber type, and address coded deviation switches available The ordinary type refers to the two-stage deviation switch mentioned above The wiring chamber type deviation switch is equipped with a waterproof wiring chamber on the basis of the ordinary type deviation switch. The on-site control cable can be directly connected to the wiring chamber to prevent faults caused by moisture and virtual connection of cable joints.
- CJZCP-2 waterproof two-stage deviation switch
- ZHUOXIN
- 24-380v
- IP65
- TT, Paypal, Credit card, Western union
- +86-15163766288
- CJZCP-2 waterproof two-level deviation switch There are ordinary type, wiring chamber type, and address coded deviation switches available The ordinary type refers to the two-stage deviation switch mentioned above The wiring chamber type deviation switch is equipped with a waterproof wiring chamber on the basis of the ordinary type deviation switch. The on-site control cable can be directly connected to the wiring chamber to prevent faults caused by moisture and virtual connection of cable joints.
Description
CJZCP-2 waterproof two-level deviation switch Structural characteristics of CJZCP-2 waterproof two-level deviation switch:< This product adopts aluminum alloy casting shell, with high strength and light weight&
2. The shell protection level reaches IP67 and can work for a long time in harsh environments& 3. This product has sensitive movements, high stability, and reliable performance. Technical parameters:< 1. Environmental conditions for use; a. Environmental temperature: -30 ℃~70 ℃; b. Belt Switch, also known as Anti Bias Switch, has a relative humidity not exceeding 85%. Used to detect the deviation phenomenon during the operation of belt conveyors, output alarms or shutdown signals based on the actual deviation amount of the belt, which can effectively prevent accidents caused by belt deviation<
Introduction
The deviation switch plays a protective role in the belt conveyor site, so it must meet the IP protection level.< The switch is divided into two positions to detect the degree of deviation and twisting of the conveyor belt. Based on the degree of deviation and twisting of the belt, automatic alarm and shutdown are achieved to avoid accidents such as expensive conveyor belt damage and material scattering caused by belt twisting. This switch is easy to install, reliable to operate, and is one of the protective devices for belt conveyors& nbsp; Assembled thin film platinum thermistor WZP-621A, WZP-631, WZP2-621, WZP2-621A, WZP2-631, WZP-621, WZP-631, WZP2-621, WZP2-621, WZP2-631., WZP-621A, WZP2-621A, WZP-002, WZP-003, WZP-003A, WZP-010, WZP2-010, WZP-011, WZP2-011, WZC-010A, WZP-035S, WZC-001, WZC-200, WZP-260, WZP2-260, WZPM-267,WZP-269, WZP2-260, WZC-269, WZP-270, .WZC-270, WZP-280, WZP-260, WZP2-260, WZP-269, WZP2-269, WZC-269, WZC-190, WZC-890J, WZP-892, WZP2-892, WZP2-3212A,WZP2-421B,SBWZ-2481/44SI,WRN-74S,WZPK-426S,WZP-3312A,WZPK2-326SA,WZP2-6312A,WZP-6312A,WZP2-24SA,WZP-24SA,WZP2-6212A,WZP-6212A,.WZP-4312A,WZP-4212A,WZP2-3312A,WRNR-01, Thermocouple accessories WRNN-436, WRNT2-001, WRE2-12B, WZP-106S, WZP-2312A, WRE-001, WRE-002, TP-K02, WZP-2212A, WZP-203S, WZP-014S, WZP2-2312A, WRR-010, WZP2-4212A, WZP-1212A, WZP-236S waterproof junction box, WZP-270S, WRE-625, WZP-012S, K-250CD, WRP-100, WRE-010, WRE-220A, WRN-010, WRR2-010, WRN2-631, WZP2-010, WZP2-221, WZP2-220, WZP-231, WZP-230, WZP2-1312A, WZP2-106S, WRET2-31, WRN-235T, WRE-235T movable thermocouple thermal resistance, WRNR2-01, WERE2-15A, WRER2-13, WRNR2-13, WERE-13, WRNR-13, WRER2-12, WRER-01, WRNR-01, WERE2-01, WRER-12, WRET-001, WRE-625, WZPK2-535SA, WRN-15B, WRN-15B E2-14B, WRNR2-15, WRER-15, WZP-011, WZC-010A, WZP-035S, WRN-002, WRP-010, WRE-520 measuring instruments& nbsp; Laser rangefinder: TM1500, TM1000,TM800,TM600,DLE50,DLE150,LRM1200,LRM-1500,F421D,F411D,PD4,PD40,PRO1500,PRO600,PRO440,PRO6000,PR20,PML32-R,PMP34,PRI2,RL350GL,RL250GL,S2,D2,D3,A5,D5,A6,A8 ,Prexiso X2 ,Impulse 200 ,Impulse 200LR ,Impulse 200XL ,PD-4,PD-42 ,PD-40 ,NM-500,NM-600,NM-700,NM-1200,NM-1500,1200S, Ultrasonic rangefinder: ST820, ST822,AR-811,AT-831,AR-841,AR-851, Distance measuring instrument: VC850, VICTOR 851,600VR,600VH,1500VR,1500VH,1500VR/VH,1000VR/VH,800VR/VH,600VR/VH , Altimeter& nbsp; 6000E,2000E,SIR-600E,600E,AR-600E ,CHM6000, Illuminance meter& nbsp; UV illuminometer: TN-340, ST510,ST512,ST513,TN2340,YK-34UV,BK-8732,UVAB513,UV-365HA,UV-340A,UVA-365,UVC-254,YK-35UV,UV-365, Illumination meter: DE-350, VA-8050,AK-820,* 3640-20,* 3423,MS6610,* 5202,* 5201,F941,MS6610,BK-8332,BK-8630,BK8731,BK-8331,LX-101A,LX-102,LX-107,DT1308,DT1309,DT8809,DT8809A,VICTOR 1010,LX101,TES-1330A,* 3640-20,AR-813,AR-823,DT-8808,TES-1332,TES-1334,TES-1336,LX-9621,LX-9626, Atomic absorption spectrophotometer: LAB800, LAB700,LAB600M,LAB600H,LAB600,LAB500,LAB400,LAB300,LAB200,LAB100,HG--9602A,HG—9602,HG--9602B,HG—9601, Digital illuminometer: DE-3351, DE-3350,LX-1102,LX-105,LX-103 ,UT-381,UT-382,TES-1335,TES-1339,TN-1330,YF-1065,YF-170,CENTER-337,
2. The shell protection level reaches IP67 and can work for a long time in harsh environments& 3. This product has sensitive movements, high stability, and reliable performance. Technical parameters:< 1. Environmental conditions for use; a. Environmental temperature: -30 ℃~70 ℃; b. Belt Switch, also known as Anti Bias Switch, has a relative humidity not exceeding 85%. Used to detect the deviation phenomenon during the operation of belt conveyors, output alarms or shutdown signals based on the actual deviation amount of the belt, which can effectively prevent accidents caused by belt deviation<
Introduction
The deviation switch plays a protective role in the belt conveyor site, so it must meet the IP protection level.< The switch is divided into two positions to detect the degree of deviation and twisting of the conveyor belt. Based on the degree of deviation and twisting of the belt, automatic alarm and shutdown are achieved to avoid accidents such as expensive conveyor belt damage and material scattering caused by belt twisting. This switch is easy to install, reliable to operate, and is one of the protective devices for belt conveyors& nbsp; Assembled thin film platinum thermistor WZP-621A, WZP-631, WZP2-621, WZP2-621A, WZP2-631, WZP-621, WZP-631, WZP2-621, WZP2-621, WZP2-631., WZP-621A, WZP2-621A, WZP-002, WZP-003, WZP-003A, WZP-010, WZP2-010, WZP-011, WZP2-011, WZC-010A, WZP-035S, WZC-001, WZC-200, WZP-260, WZP2-260, WZPM-267,WZP-269, WZP2-260, WZC-269, WZP-270, .WZC-270, WZP-280, WZP-260, WZP2-260, WZP-269, WZP2-269, WZC-269, WZC-190, WZC-890J, WZP-892, WZP2-892, WZP2-3212A,WZP2-421B,SBWZ-2481/44SI,WRN-74S,WZPK-426S,WZP-3312A,WZPK2-326SA,WZP2-6312A,WZP-6312A,WZP2-24SA,WZP-24SA,WZP2-6212A,WZP-6212A,.WZP-4312A,WZP-4212A,WZP2-3312A,WRNR-01, Thermocouple accessories WRNN-436, WRNT2-001, WRE2-12B, WZP-106S, WZP-2312A, WRE-001, WRE-002, TP-K02, WZP-2212A, WZP-203S, WZP-014S, WZP2-2312A, WRR-010, WZP2-4212A, WZP-1212A, WZP-236S waterproof junction box, WZP-270S, WRE-625, WZP-012S, K-250CD, WRP-100, WRE-010, WRE-220A, WRN-010, WRR2-010, WRN2-631, WZP2-010, WZP2-221, WZP2-220, WZP-231, WZP-230, WZP2-1312A, WZP2-106S, WRET2-31, WRN-235T, WRE-235T movable thermocouple thermal resistance, WRNR2-01, WERE2-15A, WRER2-13, WRNR2-13, WERE-13, WRNR-13, WRER2-12, WRER-01, WRNR-01, WERE2-01, WRER-12, WRET-001, WRE-625, WZPK2-535SA, WRN-15B, WRN-15B E2-14B, WRNR2-15, WRER-15, WZP-011, WZC-010A, WZP-035S, WRN-002, WRP-010, WRE-520 measuring instruments& nbsp; Laser rangefinder: TM1500, TM1000,TM800,TM600,DLE50,DLE150,LRM1200,LRM-1500,F421D,F411D,PD4,PD40,PRO1500,PRO600,PRO440,PRO6000,PR20,PML32-R,PMP34,PRI2,RL350GL,RL250GL,S2,D2,D3,A5,D5,A6,A8 ,Prexiso X2 ,Impulse 200 ,Impulse 200LR ,Impulse 200XL ,PD-4,PD-42 ,PD-40 ,NM-500,NM-600,NM-700,NM-1200,NM-1500,1200S, Ultrasonic rangefinder: ST820, ST822,AR-811,AT-831,AR-841,AR-851, Distance measuring instrument: VC850, VICTOR 851,600VR,600VH,1500VR,1500VH,1500VR/VH,1000VR/VH,800VR/VH,600VR/VH , Altimeter& nbsp; 6000E,2000E,SIR-600E,600E,AR-600E ,CHM6000, Illuminance meter& nbsp; UV illuminometer: TN-340, ST510,ST512,ST513,TN2340,YK-34UV,BK-8732,UVAB513,UV-365HA,UV-340A,UVA-365,UVC-254,YK-35UV,UV-365, Illumination meter: DE-350, VA-8050,AK-820,* 3640-20,* 3423,MS6610,* 5202,* 5201,F941,MS6610,BK-8332,BK-8630,BK8731,BK-8331,LX-101A,LX-102,LX-107,DT1308,DT1309,DT8809,DT8809A,VICTOR 1010,LX101,TES-1330A,* 3640-20,AR-813,AR-823,DT-8808,TES-1332,TES-1334,TES-1336,LX-9621,LX-9626, Atomic absorption spectrophotometer: LAB800, LAB700,LAB600M,LAB600H,LAB600,LAB500,LAB400,LAB300,LAB200,LAB100,HG--9602A,HG—9602,HG--9602B,HG—9601, Digital illuminometer: DE-3351, DE-3350,LX-1102,LX-105,LX-103 ,UT-381,UT-382,TES-1335,TES-1339,TN-1330,YF-1065,YF-170,CENTER-337,
Tags
Get the latest price? We'll respond as soon as possible(within 12 hours)