Conveyor switch

Mining sealed magnetic induction shaft switch KGE1-1P

Mining sealed magnetic induction shaft switch KGE1-1P
Mine magnetic switch, also known as mine hoist cage positioning switch, is used to locate the cage position as the name suggests. In general applications, it is used in conjunction with permanent magnets. A magnet is installed in a fixed position on the cage, and a magnetic switch is installed on the well wall at the position to be measured during the cage lifting process. When the cage reaches the measured position during the lifting operation, the magnetic switch installed on the well wall at that position can induce action with the magnet on the cage, transmit information to the operator through a signal line, and the cage will change its operating speed according to the system settings.

  • KGE1-1P
  • ZHUOXIN
  • 24v-110v-220v-380v
  • IP65
  • TT, Paypal, Credit card, Western union
  • +86-15163766288
  • Mining sealed magnetic induction shaft switch KGE1-1P
    Mine magnetic switch, also known as mine hoist cage positioning switch, is used to locate the cage position as the name suggests. In general applications, it is used in conjunction with permanent magnets. A magnet is installed in a fixed position on the cage, and a magnetic switch is installed on the well wall at the position to be measured during the cage lifting process. When the cage reaches the measured position during the lifting operation, the magnetic switch installed on the well wall at that position can induce action with the magnet on the cage, transmit information to the operator through a signal line, and the cage will change its operating speed according to the system settings.

Description

Conveyor switch

Mining sealed magnetic induction shaft switch KGE1-1P; Usage: Mine magnetic switch, also known as mine hoist cage positioning switch, as the name suggests, is used to locate the position of the cage. In general applications, it is used in conjunction with permanent magnets. Install the magnet in a fixed position on the cage, and install the magnetic switch on the cage; During the lifting process, when the cage reaches the position to be measured on the wellbore wall, the magnetic switch installed on the wellbore wall at that position can induce action with the magnet on the cage, and transmit information to the operator through a signal line. The cage will adjust its operating speed according to the system settings. This switch element can facilitate operators to control the lifting speed of the hoist cage, improve work efficiency, and prevent transportation and lifting accidents. It is a component of the mine hoist. Selection of KGE1-1P material structure shell for mining sealed magnetic induction switch: Based on experimental data, under the same conditions, the rectangular pressure is small. Considering underground operations and requirements, the selection is for a rectangular shell< Shell material: According to the shell material, it is divided into copper shell, stainless steel shell, and aluminum shell. The application of products with copper shells is because copper is a common metal material with strong anti magnetic properties< Internal structure: The giant reluctance chip is installed on the end face of the switch, and all components are cured in the switch housing with military grade epoxy resin sealing adhesive, which is moisture-proof, dust-proof, corrosion-proof, and shockproof. The shell leads out an eight core cable. On one side of the switch housing is a nameplate, and on the other side are two light-emitting diodes indicating the working status, which light up when the switch is activated&
Model Classification
Currently, the main magnetic switches on the market are the TCK series and KGE series. These model classifications are mainly used in the immature stage of the product, to distinguish various products with different voltage ranges and performance. With the continuous improvement and increasing maturity of technology, voltage ranges and characteristics have become the performance of mining magnetic switches, without distinction. Therefore, our company's products are available for all customers to choose from and can be customized according to their requirements for detection distance and delay display. Welcome customers to call and place orders< Product model
TCK-1P universal magnetic switch
TCK-1T magnetic switch
TCK-T/ZC wellbore magnetic switch
KGE1-1P mining sealed magnetic induction switch
Model number explanation
& 1. TCK and KGE have no physical meaning, they are just model numbers< 2. The suffix number represents the output type, where 1 is a single output and 2 is a dual output< 3. The suffix characters T and P were used to distinguish products used in various voltage ranges when wide voltage designs were not used in the early years. After adopting a wide voltage design, the suffix character loses its original meaning and is defined by most manufacturers as a regular type P and a type T. Because our company's products are all wide voltage products, no distinction is made unless requested by the customer< Installation and Use of KGE1-1P Mining Sealed Magnetic Induction Switch
The installation of mining magnetic switches should be determined according to the needs of the mine users. Generally, the installation position is mainly at the wellhead end, the middle position of the wellbore, and the bottom of the wellbore. The installation and usage precautions for the body are as follows:
1.  Firstly, when installing the matching magnet and cage, an aluminum plate should be clamped in the middle to prevent the magnet from magnetizing the cage< br />2.   When installing magnetic switches, excessive impact force such as striking or throwing the switch should not be applied< br />3.  Avoid using magnetic switches in environments with strong magnetic fields and high currents (such as large magnets, welding machines, etc.)< br />4.  Do not merge the connecting wires with the power line< br />5.  Magnetic switches should not be exposed to water or coolant. If used in this environment, a cover can be used to cover it< When wiring, the wires should not withstand tensile and bending forces. When used for movable parts such as robotic arms, wires with bending resistance should be used to avoid damage or wire breakage to the switch< 7. The wiring of magnetic switches cannot be directly connected to the power supply or connected in series to the load< 8. The load voltage and large load current should not exceed the maximum allowable capacity of the magnetic switch, otherwise its lifespan will be greatly reduced< 9. Magnetic switches with indicator lights that have contact points. When the current exceeds a high current, the light-emitting diode will be damaged; If the current is below the specified range, the light-emitting diode will dim or not light up< br />10.  For direct current, it is necessary to separate the positive and negative poles. If the wiring is reversed, the switch can be activated, but the indicator light does not light up< Characteristics of KGE1-1P potential for mining sealed magnetic induction switches: 1. Adopting new technology and aviation materials, the power consumption is only 30 milliwatts< Using magnetic pulse compression technology, the magnetic sensitivity and resolution are relatively high< 3. Adopting new technology to provide accurate and reliable positioning< 4. Using circuits and redundancy technology to reduce false alarms and false alarms in signals< 5. Adopting a wide voltage design with *, it can operate stably in situations with large voltage fluctuations. Mining sealed magnetic induction switch KGE1-1P shaft switch - Mining sealed magnetic induction shaft switch KGE1-1P& nbsp;

Tags