Conveyor switch

Tilt switch

Tilt switch (probe): When a vertically suspended tilt switch is subjected to external force and deviates from the vertical position by more than 15 degrees, the mercury contact inside the switch will act, and the normally closed contact will open. After the external force is removed, the tilt switch returns to the vertical state, and the mercury contacts close again. Use the changes in the opening and closing of the internal contacts of the tilt switch to determine the working condition of the protective equipment, and take timely measures to achieve the purpose of safety protection.

  • 20-39-25
  • ZHUOXIN
  • 24V-380V
  • IP67
  • TT, PayPal, Credit card, Western union
  • +86-15163766288
  • Tilt switches are widely used in various fields such as metallurgy, coal, cement and building materials, mining, electricity, ports, metallurgy, chemical engineering, etc., including conventional belt conveyors, underground cable support belt conveyors, ship loading and unloading systems, stacking/reclaiming conveyors, inclined and shuttle conveyors, cranes, excavators, boom limiters, skirt feeders, and other types of conveyors.

Description

Conveyor switch







20-39-25 tilt switch (probe): When a vertically suspended tilt switch is subjected to external force and deviates from the vertical position by more than 15 degrees, the mercury contact inside the switch will act and the normally closed contact will open. After the external force is removed, the tilt switch returns to the vertical state, and the mercury contacts close again. Use the changes in the opening and closing of the internal contacts of the tilt switch to determine the working condition of the protective equipment, and take timely measures to achieve the purpose of safety protection< Br/>
Features:

The oblique switch can be used alone with the probe or in conjunction with the control device

The alarm output time is adjustable, and the control device has an adjustable delay line of 0-10 seconds, which can avoid false operation of the tilt switch caused by instantaneous tilt< Br/>
The normal/alarm position can be set, and there is a jumper in the control device that can set the switch's vertical or inclined state to the normal state
Durable and corrosion-resistant

Easy to install

The control device is a printed circuit board structure

All probes are equipped with installation accessories

There is an adjustable time delay of 0-10 seconds in the control device, which can avoid misoperation of the tilt switch probe caused by instantaneous tilt< Br/>
In the control device, select vertical or inclined as the normal state through jumper selection< Br/>
Two normally open and normally closed contacts are used for external alarms or control< Br/>




Technical specifications
Power supply: 220 VAC± 10%, 47-62 Hz, 10W

Output: One DPDT contact, rated capacity 5Amp/220 VAC or 5 Amp/28VDC non inductive load

Time delay: 0-10 seconds adjustable

Jumper: allows the switch to be set to a normal state in either vertical or tilted position

Application scope:

Detection of blockages in chutes or adapters

Detection of conveyor belt deviation

Dumping machine unloading probe

Used for detecting material shortage or absence in belts or vibrating feeders





Technical specifications
Contact: Normally closed, mercury switch, 250mA/24 VDC non inductive load

Optional: 0.8A at 240VAC/1.5A at 120VAC

Rated temperature: -40 ℃~+300 ℃

Shell: cast iron, surface plated with nickel chromium alloy; Tilt: Angle 15< Br/>
Chute coal blockage detectors ZGLDM-I, ZGLDM-1, LDM-I, LDM-1, ZGLDM-II, ZGLDM-2, LDM-II, LDM-2



&Nbsp;

Tags